Notifications
You must be signed in to change notification settings - Fork 15
/
Copy pathREADME.txt
251 lines (220 loc) · 10.8 KB
/
README.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
---------------------------------------------------------
Inverter Monitor Installation - as at 08Mar2012
---------------------------------------------------------
1) Download files from solarfreaks & put them in a folder
such as c:/solar/scripts (Windows) or /tmp/solar/scripts (Unix/Linux)
* config.ini - copy configs/config_*.ini for your inverter to config.ini
* create_rrd.pl - if use_rrdtool in config.ini is set to 1
* inverter.pl
* MonitorInverter.bat - Windows only
* pvoutput.pl - if use_pvoutput in config.ini is set to 1
* README.txt
* VersionInfo.txt
2) Download and Install Perl
eg: ActivePerl via http://www.activestate.com/activeperl/downloads
* Windows users: make sure the version you download contains Win32::SerialPort
http://code.activestate.com/ppm/Win32-SerialPort/
* Other users: make sure the version you download contains Device::SerialPort
http://code.activestate.com/ppm/Device-SerialPort/
3) Install Required Perl Modules
You may also need to install these, see 'Required Perl Modules' below:
a) AppConfig
b) Win32::SerialPort (Windows)
c) Device::SerialPort (Unix/Linux/Other)
eg: http://docs.activestate.com/activeperl/5.12/faq/ActivePerl-faq2.html
4) Download and Install rrdtool if 'use_rrdtool' is set to 1:
http://oss.oetiker.ch/rrdtool/download.en.html
5) Setup your pvoutput settings per http://pvoutput.org/help.html#api
6) Open pvoutput.pl in notepad and enter your details for SERIAL_NUM, API_KEY & SYSTEM_ID
per your pvoutput settings in step 3.
7) Open the configuration settings file (config.ini) and edit it *IF REQUIRED*
but be careful to leave it in the SAME format.
8) Run the script, eg for Windows:
* Double click MonitorInverter.bat to run it
or
* Start > Run > cmd > cd c:/solar/scripts > perl inverter.pl "COM1"
9) Set up a Windows Scheduled Task (or a Linux/Unix Cronjob), eg:
* For Linux
crontab -e
Add row: */5 3-22 * * * pgrep -f "\./inverter.pl" > /dev/null || ( cd /tmp/solar/solar && ./inverter.pl >> inverter.pl.cronout 2>&1 )
* For Windows
* Start (or My Computer) -> Control Panel -> Scheduled Tasks -> Add Scheduled Task ... etc
or
* Start -> All Programs -> Administrative Tools -> Task Scheduler -> Action -> New Task ->
General (tab) ->
Name: SolarInverterMonitor
Description: Attempt to fire up the solar inverter monitor.
Select 'Run whether user is logged on or not' and 'Do not store password.'
Select 'Run with highest privileges.'
Triggers (tab) -> New ->
Begin the task: 'On a schedule'
Settings: 'Daily' '5:00:00 AM'. Recur every: 1 days.
Repeat task every: '5 minutes' for a duration of: '1 day' (or 'Indefinitely')
'Enabled'
-> OK.
Actions (tab) -> New ->
Action: 'Start a program'
Program/script: InverterMonitor.bat
Start in: C:\solar\scripts
-> OK.
Conditions (tab) ->
choose your own options.
Settings (tab) ->
'Allow task to be run on demand'
'Stop the task if it runs longer than: '3 days'
If the task is already running, then the following rule applies: 'Do not start a new instance'
-> OK
NOTE: If you need to kill the process manually: open Task Manager > Processes > Tick 'Show Processes from all users' > right click 'perl.exe' > select 'End Process'.
Links:
* http://www.iopus.com/guides/winscheduler.htm
* http://lifehacker.com/153089/hack-attack-using-windows-scheduled-tasks
* http://windows.microsoft.com/en-US/windows-vista/Schedule-a-task
---------------------------------------------------------
Output Filenames
---------------------------------------------------------
* inverter_[serial#]_YYYYMMDD.csv
* inverter_err_[serial#]_YYYYMM.csv
* inverter_[serial#].rrd
---------------------------------------------------------
Basic Perl Commands - on the Command Line
---------------------------------------------------------
You can run perl commands in a 'command/dos' window, eg: Start > Run > cmd (Windows)
* Get Perl version: perl -v
* Check file's syntax: perl -wc perltest.pl
* Run a script: perl perltest.pl
---------------------------------------------------------
Required Perl Modules
---------------------------------------------------------
Windows:
* install any missing modules if required
- using ActivePerl Package Manager:
Start > All Programs > ActivePerl > Perl Package Manager > View > All Packages >
right click 'AppConfig' > Install
right click 'Win32-SerialPort' > Install
File > Run Marked Actions > OK
File > Exit
OR
- manually:
* check if modules already installed:
perl -MAppconfig -e "print 'OK'"
perl -MWin32::SerialPort -e "print 'OK'"
* install them if not already:
ppm.bat install AppConfig
ppm.bat install Win32-SerialPort
Unix/Linux/Other:
* install any missing modules if required
- using ActivePerl Package Manager:
Type 'ppm' on the command line to launch it's GUI eg:
http://docs.activestate.com/activeperl/5.12/faq/ActivePerl-faq2.html#ppm_gui
OR
- manually:
sudo apt-get install libappconfig-perl
sudo apt-get install libdevice-serialport-perl
---------------------------------------------------------
Sample Output
---------------------------------------------------------
The hex serial number in this output has been replaced with "00112233445566778899"
and the serial number has been replaced with "0123456789". :)
C:\Windows\system32>cd c:\solar\scripts
c:\solar\scripts>perl inverter.pl "COM1"
Starting up at 21/05/2011 09:57:19 running on MSWin32 ...
Initialise Serial Port... port = COM1
Send -> req init inverter: aaaa010000000004000159
Send -> req serial: aaaa010000000000000155
Recv <- aaaa0000010000800a001122334455667788990409
Send -> confirm serial: aaaa0100000000010b001122334455667788993301038c
Recv <- aaaa000101000081010601de
Send -> req version: aaaa01000001010300015a
Recv <- aaaa000101000183403120203230303041412e303020202020434d532032303030202020
2050484f454e495854454320202020202000112233445566778899000000000000333630300dcc
* Version info:
asciiVers=¬¬ ?? ?â@1 2000AA.00 CMS 2000 PHOENIXTEC 0123456789 3
¦00
CAPACITY : 2000
FIRMWARE : AA.00
MANUF : PHOENIXTEC
MODEL : CMS 2000
OTHER : 3600
SERIAL : 0123456789
Send -> req param format: aaaa010000010101000158
Recv <- aaaa000101000181064041444546470375
* Parameter Format:
dataToFollow = hex(06) = 6
9 = 40 = VPV-START = 0 = PV Start-up voltage
10 = 41 = T-START = 1 = Time to connect grid
11 = 44 = VAC-MIN = 2 = Minimum operational grid voltage
12 = 45 = VAC-MAX = 3 = Maximum operational grid voltage
13 = 46 = FAC-MIN = 4 = Minimum operational frequency
14 = 47 = FAC-MAX = 5 = Maximum operational frequency
Send -> req params: aaaa01000001010400015b
Recv <- aaaa0001010001840c05dc003c080c0a5012c014b4050c
* Parameters:
VPV-START : 150 V = PV Start-up voltage
T-START : 60 Sec = Time to connect grid
VAC-MIN : 206 V = Minimum operational grid voltage
VAC-MAX : 264 V = Maximum operational grid voltage
FAC-MIN : 48 Hz = Minimum operational frequency
FAC-MAX : 53 Hz = Maximum operational frequency
Send -> req data format: aaaa010000010100000157
Recv <- aaaa00010100018015000d4041424344454748494a4c78797a7b7c7d7e7f08d2
* Data Format:
dataToFollow = hex(15) = 21
9 = 00 = TEMP = 0 = Internal Temperature
10 = 0d = ETODAY = 1 = Accumulated Energy Today
11 = 40 = VPV = 2 = Panel Voltage
12 = 41 = IAC = 3 = Grid Current
13 = 42 = VAC = 4 = Grid Voltage
14 = 43 = FAC = 5 = Grid Frequency
15 = 44 = PAC = 6 = Output Power
16 = 45 = ZAC = 7 = Grid Impedance
17 = 47 = ETOTALH = 8 = Accumulated Energy (high bit)
18 = 48 = ETOTALL = 9 = Accumulated Energy (low bit)
19 = 49 = HTOTALH = 10 = Working Hours (high bit)
20 = 4a = HTOTALL = 11 = Working Hours (low bit)
21 = 4c = MODE = 12 = Operating Mode
22 = 78 = ERR_GV = 13 = Error message: GV fault value
23 = 79 = ERR_GF = 14 = Error message: GF fault value
24 = 7a = ERR_GZ = 15 = Error message: GZ fault value
25 = 7b = ERR_TEMP = 16 = Error message: Tmp fault value
26 = 7c = ERR_PV1 = 17 = Error message: PV1 fault value
27 = 7d = ERR_GFC1 = 18 = Error message: GFC1 fault value
28 = 7e = ERR_MODE = 19 = Error mode
29 = 7f = UNK10 = 20 = Unknown
Send -> req data as at 21/05/2011 09:57:27 : aaaa010000010102000159
Recv <- aaaa0001010001822a012d003a0c77001e09c01392030affff00001e5b00000635000100
000000000000000000000000000000073a
* Data:
TEMP : 30.1 deg C = Internal Temperature
ETODAY : 0.58 kWh = Accumulated Energy Today
VPV : 319.1 V = Panel Voltage
IAC : 3 A = Grid Current
VAC : 249.6 V = Grid Voltage
FAC : 50.1 Hz = Grid Frequency
PAC : 778 W = Output Power
ZAC : 65535 mOhm = Grid Impedance
ETOTALH : 0 kWh = Accumulated Energy (high bit)
ETOTALL : 777.1 kWh = Accumulated Energy (low bit)
HTOTALH : 0 hrs = Working Hours (high bit)
HTOTALL : 1589 hrs = Working Hours (low bit)
MODE : 1 = Operating Mode
ERR_GV : 0 = Error message: GV fault value
ERR_GF : 0 = Error message: GF fault value
ERR_GZ : 0 = Error message: GZ fault value
ERR_TEMP: 0 = Error message: Tmp fault value
ERR_PV1 : 0 = Error message: PV1 fault value
ERR_GFC1: 0 = Error message: GFC1 fault value
ERR_MODE: 0 = Error mode
UNK10 : 0 = Unknown
Logging to: C:/solar/inverter_0123456789_20110521.csv
Ran: C:/rrdtool/rrdtool update C:/solar/inverter_0123456789.rrd 1305935848:30.1:
319.1:3:249.6:50.1:778:777.1:1589:1:0.58
PVOUTPUT as at 21/05/2011 09:57:29 ...
ran: perl pvoutput.pl 580 778 20110521 09:57 0123456789
Sending to PVOUTPUT [ d => 20110521, t => 09:57, v1 => 580, v2 => 778 ]
---------------------------------------------------------
Serial Communication Protocol files - to help reverse engineer protocols for other inverters
---------------------------------------------------------
Free program from HHD software: http://www.serial-port-monitor.com/
Runs in parallel with the Inverter Control software (eg: ProControl or SunEzy Control, etc).
Start the monitor program first, then the Inverter Control software, log some stuff, close the Inverter Control program, close the monitor program.
Just copy paste from 'output' window in the monitor program & paste it into your own text file (Notepad) & save it.